Broadband Optimized Protection

Pxxx0ECMC

  • Electrical Characteristics
    • Catalog # P0080ECMC
    • Obsolete: 2009 -08-03
    • Replaced By: P0080ECMCL
    • VDRM T-R
      (V)
      6
    • VS T-R
      (V)
      25
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      75
    • CO 2V
      T-R MIN
      (pF)
      35
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 50
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Catalog # P0080ECMCL
    • VDRM T-R
      (V)
      6
    • VS T-R
      (V)
      25
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      75
    • CO 2V
      T-R MIN
      (pF)
      35
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 50
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P0300ECMC
    • Obsolete: 2009 -08-03
    • Replaced By: P0300ECMCL
    • VDRM T-R
      (V)
      25
    • VS T-R
      (V)
      40
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      45
    • CO 2V
      T-R MIN
      (pF)
      25
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 50
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Catalog # P0300ECMCL
    • VDRM T-R
      (V)
      25
    • VS T-R
      (V)
      40
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      45
    • CO 2V
      T-R MIN
      (pF)
      25
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 50
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P0640ECMC
    • Obsolete: 2009 -08-03
    • Replaced By: P0640ECMCL
    • VDRM T-R
      (V)
      58
    • VS T-R
      (V)
      77
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      85
    • CO 2V
      T-R MIN
      (pF)
      55
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Catalog # P0640ECMCL
    • VDRM T-R
      (V)
      58
    • VS T-R
      (V)
      77
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      85
    • CO 2V
      T-R MIN
      (pF)
      55
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P0720ECMC
    • Obsolete: 2009 -08-03
    • Replaced By: P0720ECMCL
    • VDRM T-R
      (V)
      65
    • VS T-R
      (V)
      88
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      75
    • CO 2V
      T-R MIN
      (pF)
      50
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Catalog # P0720ECMCL
    • VDRM T-R
      (V)
      65
    • VS T-R
      (V)
      88
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      75
    • CO 2V
      T-R MIN
      (pF)
      50
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P0900ECMC
    • Obsolete: 2009 -08-03
    • Replaced By: P0900ECMCL
    • VDRM T-R
      (V)
      75
    • VS T-R
      (V)
      98
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      70
    • CO 2V
      T-R MIN
      (pF)
      45
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Catalog # P0900ECMCL
    • VDRM T-R
      (V)
      75
    • VS T-R
      (V)
      98
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      70
    • CO 2V
      T-R MIN
      (pF)
      45
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P1100ECMC
    • Obsolete: 2009 -08-03
    • Replaced By: P1100ECMCL
    • VDRM T-R
      (V)
      90
    • VS T-R
      (V)
      130
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      70
    • CO 2V
      T-R MIN
      (pF)
      45
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Catalog # P1100ECMCL
    • VDRM T-R
      (V)
      90
    • VS T-R
      (V)
      130
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      70
    • CO 2V
      T-R MIN
      (pF)
      45
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P1300ECMC
    • Obsolete: 2009 -08-03
    • Replaced By: P1300ECMCL
    • VDRM T-R
      (V)
      120
    • VS T-R
      (V)
      160
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      60
    • CO 2V
      T-R MIN
      (pF)
      40
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Catalog # P1300ECMCL
    • VDRM T-R
      (V)
      120
    • VS T-R
      (V)
      160
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      60
    • CO 2V
      T-R MIN
      (pF)
      40
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P1500ECMC
    • Obsolete: 2009 -08-03
    • Replaced By: P1500ECMCL
    • VDRM T-R
      (V)
      140
    • VS T-R
      (V)
      180
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      55
    • CO 2V
      T-R MIN
      (pF)
      35
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Catalog # P1500ECMCL
    • VDRM T-R
      (V)
      140
    • VS T-R
      (V)
      180
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      55
    • CO 2V
      T-R MIN
      (pF)
      35
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P1800ECMC
    • Obsolete: 2009 -08-03
    • Replaced By: P1800ECMCL
    • VDRM T-R
      (V)
      170
    • VS T-R
      (V)
      220
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      50
    • CO 2V
      T-R MIN
      (pF)
      35
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Catalog # P1800ECMCL
    • VDRM T-R
      (V)
      170
    • VS T-R
      (V)
      220
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      50
    • CO 2V
      T-R MIN
      (pF)
      35
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P2300ECMC
    • Obsolete: 2009 -08-03
    • Replaced By: P2300ECMCL
    • VDRM T-R
      (V)
      190
    • VS T-R
      (V)
      250
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      50
    • CO 2V
      T-R MIN
      (pF)
      30
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Catalog # P2300ECMCL
    • VDRM T-R
      (V)
      190
    • VS T-R
      (V)
      260
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      50
    • CO 2V
      T-R MIN
      (pF)
      30
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P2600ECMC
    • Obsolete: 2009 -08-03
    • Replaced By: P2600ECMCL
    • VDRM T-R
      (V)
      220
    • VS T-R
      (V)
      300
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      45
    • CO 2V
      T-R MIN
      (pF)
      30
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Catalog # P2600ECMCL
    • VDRM T-R
      (V)
      220
    • VS T-R
      (V)
      300
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      45
    • CO 2V
      T-R MIN
      (pF)
      30
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P3100ECMC
    • Obsolete: 2009 -08-03
    • Replaced By: P3100ECMCL
    • VDRM T-R
      (V)
      275
    • VS T-R
      (V)
      350
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      45
    • CO 2V
      T-R MIN
      (pF)
      30
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Catalog # P3100ECMCL
    • VDRM T-R
      (V)
      275
    • VS T-R
      (V)
      350
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      45
    • CO 2V
      T-R MIN
      (pF)
      30
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P3500ECMC
    • Obsolete: 2009 -08-03
    • Replaced By: P3500ECMCL
    • VDRM T-R
      (V)
      320
    • VS T-R
      (V)
      400
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      40
    • CO 2V
      T-R MIN
      (pF)
      25
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Catalog # P3500ECMCL
    • VDRM T-R
      (V)
      320
    • VS T-R
      (V)
      400
    • Pins T-R 1-2
    • CO 2V
      T-R MAX
      (pF)
      40
    • CO 2V
      T-R MIN
      (pF)
      25
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER BUILDING
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 500
    • Ipp5x320 200
    • Ipp8x20 400
    • Datasheet
    • Check Stock Order Sample