ORB Series

ORB120A160

  • Product Literature
    • Electrical Characteristics
      • Catalog # ORB120A160
      • Input Voltage (V) 120 V ac
      • Input Tolerance (%) -20% - 10%
      • Input AC Line Frequency (Hz) 50/60
      • Output Type Electromechanical relay
      • Output Form Isolated SPDT or DPDT
      • Output Load Rating (VA) 10 A resistive @ 120/240 V ac and 28 V dc; 1/3 hp @ 120/240 V ac
      • Time Delay Type Analog
      • Time Delay Range 60 s fixed
      • Time Delay Tolerance (%) ±10%
      • Reset Time (ms) ≤50
      • Initiate Time (ms) ≤70
      • Repeat Accuracy (%) ±2% or 20 ms whichever is greater
      • Setpoint vs Ambient Temperature and Operating Voltage (%) ≤±10%
      • Isolation voltage ≥1500 Vrms input to output
      • Life Electrical: 1 x 10⁵; Mechanical: 1 x 10⁷
      • Power Consumption 2.25 W
      • Termination Type 0.25 in. (6.35 mm) male quick connect terminals
      • Mounting Method Surface mount with 4 #6 (M3.5 x 0.6) screws
      • Operating Temperature -20° to 65°C (-4° to 149°F)
      • Storage Temperature (F/C) -30° to 85°C (-22° to 185°F)
      • Weight (lbs/g) 0 Kg