Trailing Cable Protection Relays

SE-134C

  • Product Literature
    • Electrical Characteristics
      • Catalog # SE-134C-00
      • Supply
        Voltage
        VAC
        120 - 240
      • Supply
        Voltage
        VDC
        120 - 240
      • Relay Contacts Config 1 Form A (N.O.); 1 Form B (N.C.); 2 Form C (N.O./N.C.)
      • IEEE Device Numbers 3GC - 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • GF Trip Level A 0.50 - 12.5
      • GF Trip Time s 0.10 - 2.5
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Resistance Grounded AC
      • Test Button Front-panel switch
      • Catalog # SE-134C-10
      • Supply
        Voltage
        VDC
        24 - 48
      • Relay Contacts Config 1 Form A (N.O.); 1 Form B (N.C.); 2 Form C (N.O./N.C.)
      • IEEE Device Numbers 3GC - 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • GF Trip Level A 0.50 - 12.5
      • GF Trip Time s 0.10 - 2.5
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Resistance Grounded AC
      • Test Button Front-panel switch
      • Catalog # SE-134C-XGC-00
      • Supply
        Voltage
        VAC
        120 - 240
      • Supply
        Voltage
        VDC
        120 - 240
      • Relay Contacts Config 1 Form A (N.O.); 1 Form B (N.C.); 2 Form C (N.O./N.C.)
      • IEEE Device Numbers 3GC - 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • GF Trip Level A 0.50 - 12.5
      • GF Trip Time s 0.10 - 2.5
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Resistance Grounded AC
      • Test Button Front-panel switch
      • Check Stock Order Sample
      • Catalog # SE-134C-XGC-10
      • Supply
        Voltage
        VDC
        24 - 48
      • Relay Contacts Config 1 Form A (N.O.); 1 Form B (N.C.); 2 Form C (N.O./N.C.)
      • IEEE Device Numbers 3GC - 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • GF Trip Level A 0.50 - 12.5
      • GF Trip Time s 0.10 - 2.5
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Resistance Grounded AC
      • Test Button Front-panel switch
      • Check Stock Order Sample