Neutral Grounding Resistors

SE-330HV

  • Product Literature
    • Electrical Characteristics
      • Catalog # SE-330HV-00-00
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-00-01
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-01-00
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; DeviceNet
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-01-01
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; DeviceNet
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-03-00
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; Ethernet (Dual RJ45)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-03-01
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; Ethernet (Dual RJ45)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-04-00
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; Ethernet (RJ45 and SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Order Sample
      • Catalog # SE-330HV-04-01
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; Ethernet (RJ45 and SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-05-00
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; Ethernet (Dual SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-05-01
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; Ethernet (Dual SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-06-00
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; IEC61850 (Dual RJ45)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Order Sample
      • Catalog # SE-330HV-06-01
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; IEC61850 (Dual RJ45)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-07-00
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; IEC61850 (RJ45 and SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-07-01
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; IEC61850 (RJ45 and SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-08-00
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; IEC61850 (Dual SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-08-01
      • Supply
        Voltage
        VAC
        65 - 265
      • Supply
        Voltage
        VDC
        85 - 275
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; IEC61850 (Dual SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-20-00
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-20-01
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-21-00
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; DeviceNet
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-21-01
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; DeviceNet
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-23-00
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; Ethernet (Dual RJ45)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-23-01
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; Ethernet (Dual RJ45)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • RF Trip
        Time Delay
        s
        12
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-24-00
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; Ethernet (RJ45 and SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-24-01
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; Ethernet (RJ45 and SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-25-00
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; Ethernet (Dual SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-25-01
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; Ethernet (Dual SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-26-00
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; IEC61850 (Dual RJ45)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-26-01
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; IEC61850 (Dual RJ45)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-27-00
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; IEC61850 (RJ45 and SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-27-01
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; IEC61850 (RJ45 and SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-28-00
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 2 Form A; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; IEC61850 (Dual SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • System type Resistance Grounded AC
      • Catalog # SE-330HV-28-01
      • Supply
        Voltage
        VAC
        28 - 52
      • Supply
        Voltage
        VDC
        36 - 72
      • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
      • Analog Output Current mA 4 - 20
      • Communications USB; IEC61850 (Dual SC Fiber)
      • New Rev Avail Now
      • Old Rev Avail No longer available
      • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 8.4 H x 3.9 W x 5.8 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching; Autoreset
      • Conformally coated Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
      • GF Trip Time s 0.1 - 10.0
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • RF Trip
        Level
        V
        100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
      • System type Resistance Grounded AC