231

231-INSIDER-P

  • Electrical Characteristics
    • Catalog # 231-INSIDER-P
    • Input Voltage (V) 230 Vac
    • Maximum Input Power 5
    • Input AC Line Frequency (Hz) 50 / 60 (50 will increase all delay timers by 20%)
    • Input Load Range (hp) 1/3 - 1
    • Output Form SPST
    • Output Load Rating (VA) 1 hp @ 240 Vac (17 A max.)
    • Rapid Cycle Timer (s) 4 restarts allowed in 60 s period
    • Restart Delay Range Over/Under Voltage: 2 s; All other faults: Manual; 2 - 225 m
    • Trip Delay Range Overcurrent: 5 s; Dry-well: 4 s
    • Overvoltage Trip Voltage (%) 265 Vac
    • Undervoltage Reset Voltage (%) 190 Vac
    • Overcurrent Trip Class 125% of calibration point
    • Underload (%) Adjustable (70 to 90% of calibrated run power)
    • Mounting Method Inside a Franklin™; Pente®; or CentriPro™ control box
    • Operating Temperature -40° to 55°C (-40° to 131°F)
    • Weight (lbs/g) 0 Kg
    • Check Stock Yes