Ground Fault Relays

SE-703

  • Product Literature
    • Electrical Characteristics
      • Catalog # SE-703-03-00
      • Supply
        Voltage
        VAC
        24
      • Relay Contacts Config 2 Form C
      • Analog Output Voltage V 0 - 5 V
      • IEEE Device Numbers 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe
      • Dimensions 3 H x 2.2 W x 4.5 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching
      • Conformally coated Optional
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Solidly Grounded AC; Resistance Grounded AC
      • Test Button Front-panel switch
      • Order Sample
      • Catalog # SE-703-03-02
      • Supply
        Voltage
        VAC
        24
      • Relay Contacts Config 2 Form C
      • Analog Output Voltage V 0 - 5 V
      • IEEE Device Numbers 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 3 H x 2.2 W x 4.5 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching
      • Conformally coated Optional
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Solidly Grounded AC; Resistance Grounded AC
      • Test Button Front-panel switch
      • Order Sample
      • Catalog # SE-703-0D
      • Obsolete: 2018 -08-14
      • Supply
        Voltage
        VDC
        12 - 24
      • Relay Contacts Config 1 Form A (N.O.); 1 Form B (N.C.)
      • Analog Output Voltage V 0 - 5 V
      • IEEE Device Numbers 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe
      • Dimensions 3 H x 2.2 W x 4.5 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching
      • Conformally coated Optional
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • GF Trip Level A 0.025 - 0.5
      • GF Trip Time s 0.05 - 0.5
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Solidly Grounded AC; Resistance Grounded AC
      • Test Button Front-panel switch
      • Catalog # SE-703-0D-00
      • Supply
        Voltage
        VDC
        12 - 24
      • Relay Contacts Config 2 Form C
      • Analog Output Voltage V 0 - 5 V
      • IEEE Device Numbers 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe
      • Dimensions 3 H x 2.2 W x 4.5 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching
      • Conformally coated Optional
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Solidly Grounded AC; Resistance Grounded AC
      • Test Button Front-panel switch
      • Order Sample
      • Catalog # SE-703-0D-02
      • Supply
        Voltage
        VDC
        12 - 24
      • Relay Contacts Config 2 Form C
      • Analog Output Voltage V 0 - 5 V
      • IEEE Device Numbers 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 3 H x 2.2 W x 4.5 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching
      • Conformally coated Optional
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Solidly Grounded AC; Resistance Grounded AC
      • Test Button Front-panel switch
      • Order Sample
      • Catalog # SE-703-0T
      • Obsolete: 2018 -08-14
      • Supply
        Voltage
        VDC
        48
      • Relay Contacts Config 1 Form A (N.O.); 1 Form B (N.C.)
      • Analog Output Voltage V 0 - 5 V
      • IEEE Device Numbers 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe
      • Dimensions 3 H x 2.2 W x 4.5 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching
      • Conformally coated Optional
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 1 - 99% of CT-Primary Rating
      • GF Trip Time s 0.5 - 2.5
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Solidly Grounded AC; Resistance Grounded AC
      • Test Button Front-panel switch
      • Catalog # SE-703-0T-00
      • Supply
        Voltage
        VDC
        48
      • Relay Contacts Config 2 Form C
      • Analog Output Voltage V 0 - 5 V
      • IEEE Device Numbers 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe
      • Dimensions 3 H x 2.2 W x 4.5 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching
      • Conformally coated Optional
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Solidly Grounded AC; Resistance Grounded AC
      • Test Button Front-panel switch
      • Order Sample
      • Catalog # SE-703-0T-02
      • Supply
        Voltage
        VDC
        48
      • Relay Contacts Config 2 Form C
      • Analog Output Voltage V 0 - 5 V
      • IEEE Device Numbers 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 3 H x 2.2 W x 4.5 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching
      • Conformally coated Optional
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Solidly Grounded AC; Resistance Grounded AC
      • Test Button Front-panel switch
      • Order Sample
      • Catalog # SE-703-0U
      • Obsolete: 2018 -08-14
      • Supply
        Voltage
        VAC
        120 / 240
      • Supply
        Voltage
        VDC
        120 / 240
      • Relay Contacts Config 1 Form A (N.O.); 1 Form B (N.C.)
      • Analog Output Voltage V 0 - 5 V
      • IEEE Device Numbers 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe
      • Dimensions 3 H x 2.2 W x 4.5 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching
      • Conformally coated Optional
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • GF Trip Level Range pct 1 - 99% of CT-Primary Rating
      • GF Trip Time s 0.5 - 2.5
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Solidly Grounded AC; Resistance Grounded AC
      • Test Button Front-panel switch
      • Catalog # SE-703-0U-00
      • Supply
        Voltage
        VAC
        120 / 240
      • Supply
        Voltage
        VDC
        120 / 240
      • Relay Contacts Config 2 Form C
      • Analog Output Voltage V 0 - 5 V
      • IEEE Device Numbers 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe
      • Dimensions 3 H x 2.2 W x 4.5 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching
      • Conformally coated Optional
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Solidly Grounded AC; Resistance Grounded AC
      • Test Button Front-panel switch
      • Order Sample
      • Catalog # SE-703-0U-02
      • Supply
        Voltage
        VAC
        120 / 240
      • Supply
        Voltage
        VDC
        120 / 240
      • Relay Contacts Config 2 Form C
      • Analog Output Voltage V 0 - 5 V
      • IEEE Device Numbers 50G - 50N - 51G - 51N
      • Relay
        Contact
        Operating
        Fail-safe / Non Fail-safe
      • Dimensions 3 H x 2.2 W x 4.5 D in.
      • Weight (lbs/g) 0 Kg
      • Auto Manual Reset Latching
      • Conformally coated Optional
      • CT Loop Monitoring Standard
      • Frequency 50; 60; ASD
      • Harmonic Filtering Standard (DFT)
      • Reset Type Front-panel switch/Remote N.O. Contact
      • System type Solidly Grounded AC; Resistance Grounded AC
      • Test Button Front-panel switch
      • Order Sample