FB120A FB230A

FB230A

  • Product Literature
    • Electrical Characteristics
      • Catalog # FB230A
      • Input Voltage (V) 230 V ac
      • Input Tolerance (%) ±15%
      • Input AC Line Frequency (Hz) 50/60
      • Output Form 3 total: 1 relay and 2 solid state
      • Output Load Rating (VA) One isolated SPDT relay rated 5 A resistive; Two solid-state line voltage outputs rated 0.5 A steady and 5 A inrush
      • Trip Delay Range Flasher failure: Fixed at 6 s; -0/+40; Lamp failure: Fixed at 10 s; -0/+40%
      • Lamp Socket Voltage (%) ±10%; 50/60 Hz
      • Lamp Failure Detection For two 500 W or 700 W lamps
      • Indication Lamp failure (Red): LED glows when one or both lamps fail; Flasher failure (Red): LED glows when the flasher fails
      • Circuitry Encapsulated
      • Operating Temperature -55° to 65°C (-67° to 149°F)
      • Storage Temperature (F/C) -55° to 85°C (-67° to 185°F)
      • Mounting Method Surface mount with two #6 (M3.5 x 0.6) screws
      • Termination Type 7 position barrier block for 20 AWG (0.5 mm²) to 14 AWG (2.5 mm²) wire
      • Dimensions 3.5 H x 2.5 W in. (88.9 x 63.5 mm)
      • Weight (lbs/g) 0 Kg