2920L

2920L125

  • Application Spotlight
    • Electrical Characteristics
      • Catalog # 2920L125
      • Hold Current (A) 1.25
      • Trip Current (A) 2.5
      • Max Voltage Rating 15
      • Max Fault Current Rating (A) 40
      • Max Power Dissipation (W) 1.5
      • Minimum Resistance (RMIN) (Ohms) 0.07
      • Max Resistance (R1max) (Ohms) 0.25
      • Max Time to Trip Current (A) 8
      • Max Time to Trip Time (Sec) 2
      • Typical Resistance (RTYP) (Ohms) 0.16
      • V Rate 15
      • Partner ECAD Models 2920L125
      • Operating Temperature -40° to 85°C